Rotary Vane Pump/Pump/Diesel Pump/Vane Pump/Industrial Pump/Pd Meter/LC Meter/LC Flow Meter/Positive Displacement Flow Meter/Flow Meter

  • Accuracy: +-0.2%
  • Measuring Media: Liquid
  • Sensor: No Pulsar

Self priming rotary vane pump with internal by-pass valve. The pumps use a rotor with sliding vanes to draw the liquid. The material of construction is nodular iron with sliding vanes built in a special self lubricating material.Due to its efficiency the pumps can handle viscous and aiso volatile liquids and require less horsepower than other equivalent pumps.The pumps are capable of higher flow-rates at lower number of revolutions than other designs. 
Size:

50mm/2" 
65mm/2.5" 
80mm/3" 
100mm/4" 
 



Function:CJF series lab magnetic stirred autoclave is a stirring and reacting device and this series of stirred reactors has been designed for users who need higher operating pressure.

It is used for kinds of chemical materiasl which are Gas-liquid, liquid-liquid, liquid-solid or gas-liquid-solid three-phase to react and stir fully under the high pressure, vacuum, high temperature, up to strength mass and heat transfer process.

Temperature from Room temp to 350 Degree C
Pressure from 0.1 Mpa to 35Mpa.


Usage and Range
CJF series sealing High Pressure Reactor Autoclave is a stirring and reacting device, which is used for kinds of chemical materiasl which are Gas-liquid, liquid-liquid, liquid-solid or gas-liquid-solid three-phase to react and stir fully under the high pressure, vacuum, high temperature, up to strength mass and heat transfer process.

Notes: 
1. Reaction medium should not exceed the kettle of two-thirds surface!
2. At work or at the end, demolition is strictly prohibited! Kettle is strictly prohibited in the case of ultra-pressure, high-temperature work!
3. When cleaning up autoclave, special attention should be paid not to heat water or other liquid spills into the furnace to prevent heating stove burned. If heat jacketed heat-conducting oil, don`t add water or other liquids during add heat conduction. Shall check the oil level of heat-conducting oil from time to time!
4. If internal of insulation shell has abnormal noise during operation, should be shut down, and check the mixing system whether is exception. Periodic checks shaft mixing swing. If the swing is too large, should be timely replacement of bearings or sliding bushings!

Without Lifting High Pressure Reactor

Sealing high pressure reactor autoclave Static sealing high pressure reactor autoclave stainless steel high pressure reactor autoclave factory direct high pressure reactor autoclave Lab high pressure reactor autoclave

Zhengzhou Keda Machinery and Instrument Equipment Co., Ltd , http://www.zzkdrotovapor.com