3 Part Differential 22 Parameters Auto Hematology Analyzer

Model NO.: HP-HEMA6000
Parameter: 22
Model No: HP-Hema6000
Voltage: 98V-264V
Operating Temperature: 10 Oc -35oc
Trademark: hepomed
Transport Package: Neutral Exporting Package
Specification: ce iso sgs
Origin: Zhengzhou of Henan

HP-HEMA6000 Automatic Hematology Analyzer is mainly designed to detect the parameters of the series of red blood cells and hemoglobin,platelet and leukocyte in the blood.It is a requisite vitro diagnostic equipment which is applied to quantitative analysis of blood cells in clinical and laboratory.
Model HP-HEMA6000
Voltage 98V-264V 

Advantages:
1,Fully automated to increase productivity
2,3-part differential cell counter with 22 parameter and laser light source
3,Direct tube sampling from original collection vials for operator safety
4,Bar code capability to reduce manual input
5,Proven technology to provide accurate results
6,More than 60 samples per hour
7,Minimum maintenance required

The machine is mainly used for the quantitative measurement of the blood in the 19 parameters and 3 histograms:
1   The total amount of WBC                                                                                  WBC
2   The amount of Lymphocyte                                                                               Ly#
3   The amount of Monocyte                                                                                   MO#
4   The amount of Granulocyte                                                                               GR#
5   Lymphocyte percentage                                                                                    Ly%
6   The percentage of mononuclear cells                                                              MO%
7   Granulocyte percentage                                                                                    GR%
8   The total amount of red blood cells                                                                  RBC
9   Hemoglobin                                                                                                        HGB
10   Hematocrit                                                                                                        HCT
11   Mean volume of red blood cells                                                                     MCV
12   Mean corpuscular hemoglobin                                                                      MCH
13   Mean corpuscular hemoglobin concentration                                              MCHC
14   Red blood cell volume distribution width Coefficient of variation              RDW-cv
15   The standard deviation of red blood cell volume distribution width           RDW-sd
16   The total amount of platelet                                                                            PLT
17   Mean platelet volume                                                                                      MPV 
18   Plateletcrit                                                                                                        PCT
19   Platelet distribution width                                                                               PDW
20   White blood cell distribution histogram                                                        WBC Histogram
21   Red blood cell distribution histogram                                                           RBC Histogram
22   Platelet distribution histogram                                                                       PLT Histogram

Main Parameters:
 - 1.Use impedance method for RBC and platelet count 
 - 2. Cyanide free for Haemoglobin test
 - 3. Flow cytometry +laser light scatter + chemical dye method for WBC differential analysis
 - 4.Fully automated with an autoloader and sampler
 - 5. Should use both closed tube sampling and open tube sampling
 - 6. 2 counting mode, whole blood and pre-diluted mode
 - 7. With histograms and scattergrams for differential results
 -8. Throughput of at least 60 samples per hour 
 -9. Automatic flagging system for abnormal results and automatic sample re-run 
 -10. Automatic validation of results on a dedicated PC with at least a 10.4" colour monitor
 - 11.Data storage capacity of at least 20,000 results
 - 12.Optional integrated slide maker and on-board cytology atlas
 - 13.Optional colour printer an on-board diagnostics
 - 14.Flexible communication/connection (USB)
 - 15.Operating temperature of 10 oc -35oc and humidity of up to 85%
 -16. Floppy disc drive and DVD writer 
 -17. Power 98V-264V 
 -18. The equipment should be accompanied with all manufacturers' recommended spare parts

Supply one year quanlity guarrantee for main body and free training 2 persons for first time.Reagents can be supplied by original produced by ourselves.Various technical support and maintanance suggest by our professional application engineers and sales engineers.